-40%

IBC SFC199 95% AFUE Wall Mount Superflow Combination Boiler

$ 1953.58

Availability: 96 in stock
  • Power: Less than 100 W
  • BTU/h Heating Rating: CSA: 28.3 – 125K / DHW: 28.3 – 199k
  • Water Connection Location: Bottom
  • Brand: IBC
  • Power Source: Corded Electric, Gas, LP (Liquefied Petroleum Gas), NG (Natural Gas)
  • Color: White
  • Condition: New
  • Water Temperature Range: Space: 50F/10C – 194F/90C, DHW: 104F/40C – 149F/65C
  • Water Connection: 3/4 in NPT
  • MPN: SFC199
  • Mounting Location: Indoor, Wall
  • Item Width: 17.7 in
  • Tank Capacity: Tankless
  • Bundle Description: LP conversion kit included
  • Water Heater Profile: Compact
  • Heating System: Boiler
  • Features: Adjustable Thermostat, Compact, Digital Display, Variable Temperature, Vented, Two independent copper waterways embedded in cast aluminum block, A total of five moving parts, unparalleled in the industry, 30 year track record, two million installations worldwide, Built in bypass valve to prevent temperature fluctuations
  • Country/Region of Manufacture: Canada
  • Model: SFC199
  • Voltage: 120 V
  • Custom Bundle: Yes
  • Manufacturer Warranty: 5 Year Parts / 10 Year Heat Exchanger
  • Item Height: 36.5 in
  • Type: Residential Boiler

    Description

    Simple - Reliable - Efficient
    A dual fired combi
    the SFC provides not only high-efficiency space heating, but unrivaled domestic hot water efficiency too.    We call this ‘Double HE’.  The secret lies in our patented two-in-one heat exchanger that ensures optimal heat transfer and minimal heat loss.
    Flue gases are condensed with both space heating and domestic hot water production ensuring heat extraction to the fullest extent possible.
    The SFC 199 assures you unrivaled high-efficiency and economical operation year in, year out.
    SIMPLE
    Mount > Connect > Plug-in > Enjoy endless heat & hot water
    2 independent copper waterways embedded in a cast aluminum block
    A total of 5 moving parts – Unparalleled in the industry (Fan, Pump,  Bypass Valve, Gas Valve & Damper)
    New illuminated touchscreen control display panel
    Contractor friendly, reduced internal parts, easy to install, maintain and service.
    RELIABLE
    30-year track record, 2 million installations worldwide
    Innovative state of the art electronic control
    Compatible with standard Propylene Glycol
    Built-in bypass valve to prevent temperature fluctuations (SFC 199)
    No need for a 3-way valve or secondary DHW plate heat exchanger
    Will accept a 0-10 VDC signal
    EFFICIENT
    95% AFUE with full ASME-rated heat exchanger
    Packaged with a high-efficiency variable speed pump (ECM)
    Outdoor reset technology increases efficiency by lowering the water temperature automatically
    Advanced modulating temperature control
    SPECIFICATIONS
    SFC 199
    CSA Input (Natural Gas or Propane) – MBH
    28.3 – 125
    CSA Input (Natural Gas or Propane) – KW
    8.29 – 36.6
    CSA Output – MBH
    27.1 – 111
    CSA Output – kW
    7.94 – 32.5
    DHW – CSA Input (Natural Gas or Propane) – MBH
    28.3 – 199
    DHW – CSA Input (Natural Gas or Propane) – KW
    8.29 – 58.3
    A.F.U.E
    95%
    Min gas pressure (Nat. Gas or Propane) – inch w.c.
    4
    Max Gas Pressure (Nat. Gas or Propane) – inch w.c.
    14
    Power (120Vac/60Hz) – Watts @ full fire with internal pump
    120
    Weight (empty) – lbs/Kg
    84 / 38
    Pressure vessel water content – USG/Liters
    0.19/.72
    Max boiler flow rate – USgpm
    12
    Min boiler flow rate – USgpm
    2
    Max operating pressure – Space Heating Coil – psig
    43.5
    Max operating pressure – Domestic Hot Water Coil – psig
    150
    Min water pressure – psig
    8
    Approved installation altitude – ASL
    10,000 ft
    Ambient temperature – Low (°F/°C)
    32/0
    Ambient temperature – High (°F/°C)
    122/50
    Max relative humidity (non-condensing)
    90%
    Min water temperature – Space Heating (°F/°C)
    50/10
    Max water temperature – Space Heating (°F/°C)
    194/90
    Min water temperature – Domestic Hot Water (°F/°C)
    104/40
    Max water temperature – Domestic Hot Water (°F/°C)
    149/65
    Min flow rate to activate DHW heating – USgpm
    0.5
    Max flow rate DHW heating – USgpm
    7
    Max equivalent vent length 2″ (each side)
    35′
    Max equivalent vent length 3″ (each side)
    120′
    Domestic hot water delivery: @70°F/ 39°C temp. rise
    5.0 GPM
    VENTING
    MAXIMUM EQUIVALENT LENGTH
    Schedule 40 PVC, CPVC or PPs
    (each side)
    2”
    35’
    3”
    120’
    2″ or 3″ 90′ Long Sweep Vent Elbow
    Allow 5 equivalent feet
    2″ or 3″ 90′ Short Sweep Vent Elbow
    Allow 8 equivalent feet
    2″ or 3″ 45′ Vent Elbow
    Allow 3 equivalent feet
    PPs
    PPs 87-90′ Elbow
    Allow 8 equivalent feet
    Flex PPS
    3″ PPs Flex
    (Max. 35) actual feet times 1.4
    SURFACE
    DISTANCE FROM COMBUSTABLE SURFACES
    RECOMMENDED DISTANCE FOR INSTALLATION & SERVICE
    Front
    2”
    24”
    Rear
    0”
    0”
    Left Side
    1.5”
    6”
    Right Side
    4”
    6”
    Top
    2”
    24”
    Bottom
    8”
    24”
    The SFC controller functions as an interactive touch-sensitive panel with buttons that light up, showing indicators such as numbers, icons, or letters. Some of these lit indicators signify boiler operational status. Other indicators enable you to program the boiler.
    A
    Numerical Display
    Main Display
    B
    Plus & Minus
    Temperature Adjustment
    C
    Flame
    Burner ON Indicator
    D
    Dot
    Power ON Indicator
    E
    Faucet
    DHW Indicator
    F
    Radiator
    Heating Indicator
    G
    Wrench
    Service / Reset
    H
    Return Arrow
    Enter / Save
    I
    Numerical Display
    Service